CareerExamPro

California Civil Seismic, NCEES PE/SE & BGC CIH Practice Test

ASCE 7 Equivalent Lateral Force seismic design, diaphragms & drift, LRFD steel/concrete/timber structural design, Manning's hydraulics, AASHTO roadway geometry, 3-phase power, and CIH exposure/ventilation math.

40 questions · 2 topics · start free, no sign-up

Start practising

Mixed practice drill

10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.

Timed mock exam

40 questions in 48 minutes, drawn from every topic. No answers shown until the end, then a full score breakdown, your weakest topics and a review of what you missed.

Practise by topic

Sample questions

A geotechnical investigation in Northern California measures an average shear-wave velocity in the upper 100 ft of v_s = 900 ft/s. Mapped MCE_R spectral accelerations are S_s = 1.50 and S_1 = 0.45. Relevant site coefficients for this hazard level are summarized below:

TEXT
Site Class C (1,200 < v_s <= 2,500 ft/s): F_a = 1.2, F_v = 1.5
Site Class D (600 <= v_s <= 1,200 ft/s):  F_a = 1.0, F_v = 1.8
Site Class E (v_s < 600 ft/s):            F_a = 0.9, F_v = 2.4

Assuming site-specific ground motion exceptions do not alter the tabulated factors, what are the Site Class and design spectral acceleration parameters S_DS and S_D1?

  1. Site Class D, with S_DS = 1.00 and S_D1 = 0.54 after applying the 2/3 design factor to S_MS and S_M1.
  2. Site Class D, with S_DS = 1.50 and S_D1 = 0.81, using site-adjusted MCE_R accelerations directly.
  3. Site Class C, with S_DS = 1.20 and S_D1 = 0.45, because velocities above 600 ft/s indicate very dense soil.
  4. Site Class E, with S_DS = 0.90 and S_D1 = 0.72, because soft clay profiles govern whenever v_s < 1,000 ft/s.
Show the answer

A. Site Class D, with S_DS = 1.00 and S_D1 = 0.54 after applying the 2/3 design factor to S_MS and S_M1.

Per ASCE 7 Chapter 20 (Table 20.3-1), an average shear-wave velocity of 900 ft/s falls within 600 <= v_s <= 1,200 ft/s, classifying the profile as Site Class D (Stiff Soil) with F_a = 1.0 and F_v = 1.8. Adjusting MCE_R accelerations gives S_MS = F_a * S_s = 1.0 * 1.50 = 1.50 and S_M1 = F_v * S_1 = 1.8 * 0.45 = 0.81. Applying the 2/3 design factor per ASCE 7 Section 11.4 yields S_DS = (2/3) * 1.50 = 1.00 and S_D1 = (2/3) * 0.81 = 0.54.

Reference: ASCE 7 Section 11.4 & Chapter 20 Table 20.3-1 (Site Classification & Design Spectral Accelerations)

A municipal water transmission main (L = 2,000 ft, internal diameter D = 16 in., Hazen-Williams roughness coefficient C = 120) conveys a peak-hour flow of Q = 4.0 cfs. Using the U.S. customary Hazen-Williams formula (h_f = 4.73 * L * Q^1.852 / (C^1.852 * D^4.87)), what is the friction head loss h_f across the 2,000 ft segment?

  1. 4.28 ft, with pipe diameter D = 1.333 ft and mean flow velocity V = 2.86 ft/s.
  2. 8.56 ft, applying a 2.0 safety multiplier for aging water distribution mains.
  3. 1.92 ft, entering D = 16 in. directly without converting pipe diameter into feet.
  4. 12.64 ft, squaring Q and raising D to the fifth power as in Darcy-Weisbach.
Show the answer

A. 4.28 ft, with pipe diameter D = 1.333 ft and mean flow velocity V = 2.86 ft/s.

With D = 16 / 12 = 1.3333 ft, A = pi * (1.3333)^2 / 4 = 1.396 ft^2, and V = 4.0 / 1.396 = 2.86 ft/s. Substituting into Hazen-Williams: h_f = 4.73 * 2,000 * (4.0)^1.852 / (120^1.852 * (1.3333)^4.87) = (9,460 * 13.032) / (7,090.7 * 4.058) = 123,283 / 28,774 = 4.28 ft (confirmed by V = 1.318 * C * R^0.63 * S^0.54, which also yields S * L = 4.28 ft).

Reference: NCEES PE Civil Reference Handbook (Hazen-Williams Pipe Friction Head Loss)

A new acute-care hospital expansion in California is classified as Risk Category IV (essential facility) and sits near a major fault with design spectral parameters S_DS = 0.48 and S_D1 = 0.26, and a mapped MCE_R 1-second spectral acceleration of S_1 = 0.78. What Seismic Design Category (SDC) must be assigned to this structure under ASCE 7 Section 11.6?

  1. SDC C, because S_DS is below 0.50 and short-period spectral demand governs low-rise essential facilities.
  2. SDC D, because Risk Category IV structures with S_D1 >= 0.20 always stop at SDC D unless S_DS exceeds 1.00.
  3. SDC E, because any building located on a site with mapped S_1 >= 0.75 is assigned to SDC E regardless of Risk Category.
  4. SDC F, because Risk Category IV structures located where mapped S_1 >= 0.75 are assigned directly to SDC F.
Show the answer

D. SDC F, because Risk Category IV structures located where mapped S_1 >= 0.75 are assigned directly to SDC F.

Under ASCE 7 Section 11.6, before applying Tables 11.6-1 and 11.6-2, structures located where the mapped 1-second spectral response acceleration S_1 >= 0.75 receive an automatic near-fault upgrade: Risk Categories I, II, and III are assigned to SDC E, and Risk Category IV structures are assigned to SDC F. Although S_DS = 0.48 would suggest SDC C and S_D1 = 0.26 would suggest SDC D, S_1 = 0.78 >= 0.75 for a Risk Category IV hospital mandates SDC F.

Reference: ASCE 7 Section 11.6 (Seismic Design Category Determination, Tables 11.6-1 & 11.6-2)

A 12.0-acre urban drainage basin draining to a single storm inlet consists of three land-use subareas:

TEXT
Commercial paving:  4.0 acres, runoff coefficient C = 0.85
Single-family lots: 6.0 acres, runoff coefficient C = 0.45
Neighborhood park:  2.0 acres, runoff coefficient C = 0.20

For the 25-year design storm at the basin's time of concentration (t_c = 15 min), the IDF curve gives a rainfall intensity of i = 3.50 in./hr. Using the Rational Method (Q = C * i * A), what are the area-weighted composite runoff coefficient C_w and peak discharge Q?

  1. C_w = 0.500 and Q = 21.00 cfs, taking the unweighted mean of the three C values.
  2. C_w = 0.850 and Q = 35.70 cfs, applying the highest subarea C across the entire 12-acre watershed.
  3. C_w = 0.542 and Q = 22.75 cfs, computed from the area-weighted sum of C_i * A_i.
  4. C_w = 0.542 and Q = 19.50 cfs, applying a 0.857 urban detention reduction factor.
Show the answer

C. C_w = 0.542 and Q = 22.75 cfs, computed from the area-weighted sum of C_i * A_i.

The area-weighted composite runoff coefficient is C_w = sum(C_i * A_i) / A_total = (4.0 * 0.85 + 6.0 * 0.45 + 2.0 * 0.20) / 12.0 = (3.40 + 2.70 + 0.40) / 12.0 = 6.50 / 12.0 = 0.5417 (0.542). Applying the Rational Method (1 acre-in./hr = 1.008 cfs ~ 1.0 cfs), peak runoff is Q = C_w * i * A = 0.5417 * 3.50 * 12.0 = 6.50 * 3.50 = 22.75 cfs.

Reference: NCEES PE Civil Reference Handbook / HEC-22 Urban Drainage Design Manual (Rational Method)

A 3-story steel special moment frame office building in Seismic Design Category D has only a single moment-frame bay on each perimeter line in the E–W direction, such that removing one beam-to-column connection would reduce story strength by more than 33%. Which statement accurately describes the ASCE 7 redundancy factor rho for this building?

  1. rho = 1.3 must be applied to all seismic checks in the E–W direction, including story drift, P-delta, and nonstructural anchorage.
  2. rho = 1.3 applies to E–W seismic force-resisting elements, but rho = 1.0 still applies to drift, P-delta, and nonstructural forces.
  3. rho = 1.0 applies throughout the structure because special moment frames in SDC D are automatically exempt from redundancy penalties.
  4. rho = 1.3 applies simultaneously with the overstrength factor Omega_0 when designing collectors and supporting columns.
Show the answer

B. rho = 1.3 applies to E–W seismic force-resisting elements, but rho = 1.0 still applies to drift, P-delta, and nonstructural forces.

Under ASCE 7 Section 12.3.4.2, structures in SDC D, E, or F require rho = 1.3 unless they qualify for rho = 1.0 by meeting either the element-removal criterion (no >33% strength loss and no resulting extreme torsional irregularity) or the regular two-bay perimeter framing criterion. Even when rho = 1.3 governs the seismic force-resisting system, Section 12.3.4.1 permits rho = 1.0 for drift calculations, P-delta effects, diaphragm forces (F_px unless transfer forces apply), and nonstructural components (F_p), and rho is never multiplied with Omega_0.

Reference: ASCE 7 Section 12.3.4 (Redundancy Factor rho, Conditions Where rho = 1.0)

Exams this helps with

ExamAgency / IssuerRegion
California Civil Seismic Principles Exam (BPELSG / ASCE 7)CA BPELSGUnited States
NCEES PE Civil Structural & SE Depth ExamNCEESUnited States
NCEES PE Civil Water Resources & Transportation ExamNCEESUnited States
NCEES PE Mechanical (HVAC/Thermal) & Electrical Power ExamNCEESUnited States
BGC Certified Industrial Hygienist (CIH) Comprehensive ExamBGC (ABIH)Global / Online