10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.
Timed mock exam
14 questions in 17 minutes, drawn from every topic. No answers shown until the end, then a full score breakdown, your weakest topics and a review of what you missed.
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor, calculates tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@careerexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the timed mock exam to use it.
Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.
Sample questions
A geotechnical investigation in Northern California measures an average shear-wave velocity in the upper 100 ft of v_s = 900 ft/s. Mapped MCE_R spectral accelerations are S_s = 1.50 and S_1 = 0.45. Relevant site coefficients for this hazard level are summarized below:
TEXT
Site Class C (1,200 < v_s <= 2,500 ft/s): F_a = 1.2, F_v = 1.5
Site Class D (600 <= v_s <= 1,200 ft/s): F_a = 1.0, F_v = 1.8
Site Class E (v_s < 600 ft/s): F_a = 0.9, F_v = 2.4
Assuming site-specific ground motion exceptions do not alter the tabulated factors, what are the Site Class and design spectral acceleration parameters S_DS and S_D1?
Site Class D, with S_DS = 1.00 and S_D1 = 0.54 after applying the 2/3 design factor to S_MS and S_M1.
Site Class D, with S_DS = 1.50 and S_D1 = 0.81, using site-adjusted MCE_R accelerations directly.
Site Class C, with S_DS = 1.20 and S_D1 = 0.45, because velocities above 600 ft/s indicate very dense soil.
Site Class E, with S_DS = 0.90 and S_D1 = 0.72, because soft clay profiles govern whenever v_s < 1,000 ft/s.
Show the answer
A. Site Class D, with S_DS = 1.00 and S_D1 = 0.54 after applying the 2/3 design factor to S_MS and S_M1.
Per ASCE 7 Chapter 20 (Table 20.3-1), an average shear-wave velocity of 900 ft/s falls within 600 <= v_s <= 1,200 ft/s, classifying the profile as Site Class D (Stiff Soil) with F_a = 1.0 and F_v = 1.8. Adjusting MCE_R accelerations gives S_MS = F_a * S_s = 1.0 * 1.50 = 1.50 and S_M1 = F_v * S_1 = 1.8 * 0.45 = 0.81. Applying the 2/3 design factor per ASCE 7 Section 11.4 yields S_DS = (2/3) * 1.50 = 1.00 and S_D1 = (2/3) * 0.81 = 0.54.
A new acute-care hospital expansion in California is classified as Risk Category IV (essential facility) and sits near a major fault with design spectral parameters S_DS = 0.48 and S_D1 = 0.26, and a mapped MCE_R 1-second spectral acceleration of S_1 = 0.78. What Seismic Design Category (SDC) must be assigned to this structure under ASCE 7 Section 11.6?
SDC C, because S_DS is below 0.50 and short-period spectral demand governs low-rise essential facilities.
SDC D, because Risk Category IV structures with S_D1 >= 0.20 always stop at SDC D unless S_DS exceeds 1.00.
SDC E, because any building located on a site with mapped S_1 >= 0.75 is assigned to SDC E regardless of Risk Category.
SDC F, because Risk Category IV structures located where mapped S_1 >= 0.75 are assigned directly to SDC F.
Show the answer
D. SDC F, because Risk Category IV structures located where mapped S_1 >= 0.75 are assigned directly to SDC F.
Under ASCE 7 Section 11.6, before applying Tables 11.6-1 and 11.6-2, structures located where the mapped 1-second spectral response acceleration S_1 >= 0.75 receive an automatic near-fault upgrade: Risk Categories I, II, and III are assigned to SDC E, and Risk Category IV structures are assigned to SDC F. Although S_DS = 0.48 would suggest SDC C and S_D1 = 0.26 would suggest SDC D, S_1 = 0.78 >= 0.75 for a Risk Category IV hospital mandates SDC F.
A 3-story steel special moment frame office building in Seismic Design Category D has only a single moment-frame bay on each perimeter line in the E–W direction, such that removing one beam-to-column connection would reduce story strength by more than 33%. Which statement accurately describes the ASCE 7 redundancy factor rho for this building?
rho = 1.3 must be applied to all seismic checks in the E–W direction, including story drift, P-delta, and nonstructural anchorage.
rho = 1.3 applies to E–W seismic force-resisting elements, but rho = 1.0 still applies to drift, P-delta, and nonstructural forces.
rho = 1.0 applies throughout the structure because special moment frames in SDC D are automatically exempt from redundancy penalties.
rho = 1.3 applies simultaneously with the overstrength factor Omega_0 when designing collectors and supporting columns.
Show the answer
B. rho = 1.3 applies to E–W seismic force-resisting elements, but rho = 1.0 still applies to drift, P-delta, and nonstructural forces.
Under ASCE 7 Section 12.3.4.2, structures in SDC D, E, or F require rho = 1.3 unless they qualify for rho = 1.0 by meeting either the element-removal criterion (no >33% strength loss and no resulting extreme torsional irregularity) or the regular two-bay perimeter framing criterion. Even when rho = 1.3 governs the seismic force-resisting system, Section 12.3.4.1 permits rho = 1.0 for drift calculations, P-delta effects, diaphragm forces (F_px unless transfer forces apply), and nonstructural components (F_p), and rho is never multiplied with Omega_0.