California Civil Seismic Principles & PE Civil Structural/SE practice drill
10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.
Sample questions
A geotechnical investigation in Northern California measures an average shear-wave velocity in the upper 100 ft of v_s = 900 ft/s. Mapped MCE_R spectral accelerations are S_s = 1.50 and S_1 = 0.45. Relevant site coefficients for this hazard level are summarized below:
TEXT
Site Class C (1,200 < v_s <= 2,500 ft/s): F_a = 1.2, F_v = 1.5
Site Class D (600 <= v_s <= 1,200 ft/s): F_a = 1.0, F_v = 1.8
Site Class E (v_s < 600 ft/s): F_a = 0.9, F_v = 2.4
Assuming site-specific ground motion exceptions do not alter the tabulated factors, what are the Site Class and design spectral acceleration parameters S_DS and S_D1?
Site Class D, with S_DS = 1.00 and S_D1 = 0.54 after applying the 2/3 design factor to S_MS and S_M1.
Site Class D, with S_DS = 1.50 and S_D1 = 0.81, using site-adjusted MCE_R accelerations directly.
Site Class C, with S_DS = 1.20 and S_D1 = 0.45, because velocities above 600 ft/s indicate very dense soil.
Site Class E, with S_DS = 0.90 and S_D1 = 0.72, because soft clay profiles govern whenever v_s < 1,000 ft/s.
Show the answer
A. Site Class D, with S_DS = 1.00 and S_D1 = 0.54 after applying the 2/3 design factor to S_MS and S_M1.
Per ASCE 7 Chapter 20 (Table 20.3-1), an average shear-wave velocity of 900 ft/s falls within 600 <= v_s <= 1,200 ft/s, classifying the profile as Site Class D (Stiff Soil) with F_a = 1.0 and F_v = 1.8. Adjusting MCE_R accelerations gives S_MS = F_a * S_s = 1.0 * 1.50 = 1.50 and S_M1 = F_v * S_1 = 1.8 * 0.45 = 0.81. Applying the 2/3 design factor per ASCE 7 Section 11.4 yields S_DS = (2/3) * 1.50 = 1.00 and S_D1 = (2/3) * 0.81 = 0.54.
A new acute-care hospital expansion in California is classified as Risk Category IV (essential facility) and sits near a major fault with design spectral parameters S_DS = 0.48 and S_D1 = 0.26, and a mapped MCE_R 1-second spectral acceleration of S_1 = 0.78. What Seismic Design Category (SDC) must be assigned to this structure under ASCE 7 Section 11.6?
SDC C, because S_DS is below 0.50 and short-period spectral demand governs low-rise essential facilities.
SDC D, because Risk Category IV structures with S_D1 >= 0.20 always stop at SDC D unless S_DS exceeds 1.00.
SDC E, because any building located on a site with mapped S_1 >= 0.75 is assigned to SDC E regardless of Risk Category.
SDC F, because Risk Category IV structures located where mapped S_1 >= 0.75 are assigned directly to SDC F.
Show the answer
D. SDC F, because Risk Category IV structures located where mapped S_1 >= 0.75 are assigned directly to SDC F.
Under ASCE 7 Section 11.6, before applying Tables 11.6-1 and 11.6-2, structures located where the mapped 1-second spectral response acceleration S_1 >= 0.75 receive an automatic near-fault upgrade: Risk Categories I, II, and III are assigned to SDC E, and Risk Category IV structures are assigned to SDC F. Although S_DS = 0.48 would suggest SDC C and S_D1 = 0.26 would suggest SDC D, S_1 = 0.78 >= 0.75 for a Risk Category IV hospital mandates SDC F.
A 3-story steel special moment frame office building in Seismic Design Category D has only a single moment-frame bay on each perimeter line in the E–W direction, such that removing one beam-to-column connection would reduce story strength by more than 33%. Which statement accurately describes the ASCE 7 redundancy factor rho for this building?
rho = 1.3 must be applied to all seismic checks in the E–W direction, including story drift, P-delta, and nonstructural anchorage.
rho = 1.3 applies to E–W seismic force-resisting elements, but rho = 1.0 still applies to drift, P-delta, and nonstructural forces.
rho = 1.0 applies throughout the structure because special moment frames in SDC D are automatically exempt from redundancy penalties.
rho = 1.3 applies simultaneously with the overstrength factor Omega_0 when designing collectors and supporting columns.
Show the answer
B. rho = 1.3 applies to E–W seismic force-resisting elements, but rho = 1.0 still applies to drift, P-delta, and nonstructural forces.
Under ASCE 7 Section 12.3.4.2, structures in SDC D, E, or F require rho = 1.3 unless they qualify for rho = 1.0 by meeting either the element-removal criterion (no >33% strength loss and no resulting extreme torsional irregularity) or the regular two-bay perimeter framing criterion. Even when rho = 1.3 governs the seismic force-resisting system, Section 12.3.4.1 permits rho = 1.0 for drift calculations, P-delta effects, diaphragm forces (F_px unless transfer forces apply), and nonstructural components (F_p), and rho is never multiplied with Omega_0.