CareerExamPro

BGC Certified Industrial Hygienist (CIH) Comprehensive Exam practice test

7 practice questions for this exam, each with a full explanation and cited rule or blueprint reference.

Start practising

CA Seismic, NCEES PE/SE & BGC CIH: practice drill

10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.

Practice tests that prepare you for this exam

Practise by topic

About this exam

Agency / Issuer
BGC (ABIH)
Region
Global / Online

Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.

Sample questions

An industrial spray-booth painter has full-shift 8-hour TWA personal breathing-zone exposures to three organic solvent vapors that share additive central nervous system (CNS) depressant effects:

TEXT
Toluene:           C_1 =  9 ppm,  ACGIH TLV-TWA =  20 ppm
Isopropyl alcohol: C_2 = 70 ppm,  ACGIH TLV-TWA = 200 ppm
Acetone:           C_3 = 90 ppm,  ACGIH TLV-TWA = 250 ppm

Using the ACGIH/OSHA additive mixture exposure equation (E_m = sum(C_i / TLV_i)), what is the mixture index E_m and the compliance determination?

  1. E_m = 1.16, exceeding unity (1.0) and indicating overexposure to the additive solvent mixture.
  2. E_m = 0.39, taking the average of the three fractional ratios and confirming full compliance.
  3. E_m = 0.36, computed by dividing total combined concentration (169 ppm) by the sum of all three TLVs (470 ppm).
  4. Compliant without calculating E_m, because none of the three individual vapors exceeds its standalone TLV-TWA.
Show the answer

A. E_m = 1.16, exceeding unity (1.0) and indicating overexposure to the additive solvent mixture.

When airborne contaminants act on the same target organ system (here, CNS depression), OSHA 29 CFR 1910.1000(d)(2) and ACGIH require evaluating the additive mixture index: E_m = (9 / 20) + (70 / 200) + (90 / 250) = 0.45 + 0.35 + 0.36 = 1.16. Because E_m = 1.16 > 1.0, the combined threshold limit is exceeded even though every individual vapor remained below its standalone TLV-TWA.

Reference: OSHA 29 CFR 1910.1000(d)(2) / ACGIH TLVs and BEIs (Appendix E: Threshold Limit Values for Mixtures)

During field industrial gamma radiography, a health physicist measures an unshielded point-source exposure rate of I_1 = 450 mR/hr at a distance of d_1 = 2.0 ft. Neglecting air attenuation, what minimum perimeter barricade distance d_2 is required to reduce the exposure rate to the unrestricted-area limit of I_2 = 2.0 mR/hr using the inverse-square law (I_1 * d_1^2 = I_2 * d_2^2)?

  1. 30.0 ft, computed from d_2 = d_1 * sqrt(I_1 / I_2) = 2.0 * sqrt(225).
  2. 15.0 ft, computed from sqrt(450 / 2.0) without multiplying by d_1 = 2.0 ft.
  3. 21.2 ft, squaring d_2 while leaving initial distance d_1 unsquared.
  4. 450.0 ft, assuming exposure rate decreases linearly (I_1 * d_1 = I_2 * d_2).
Show the answer

A. 30.0 ft, computed from d_2 = d_1 * sqrt(I_1 / I_2) = 2.0 * sqrt(225).

For an unshielded point source of ionizing radiation, intensity varies inversely with the square of distance: I_1 * d_1^2 = I_2 * d_2^2. Solving for d_2: d_2 = d_1 * sqrt(I_1 / I_2) = 2.0 * sqrt(450 / 2.0) = 2.0 * sqrt(225) = 2.0 * 15.0 = 30.0 ft.

Reference: 10 CFR 20.1301 / BGC CIH Equation Sheet (Ionizing Radiation Inverse-Square Law)

A foundry fettler is exposed to respirable crystalline silica at an 8-hour TWA concentration of 1,400 ug/m^3 (OSHA PEL = 50 ug/m^3; NIOSH IDLH = 50,000 ug/m^3). Under OSHA 29 CFR 1910.134 Table 1 (half-mask APR APF = 10, loose-fitting PAPR APF = 25, full-facepiece APR APF = 50, full-facepiece PAPR APF = 1,000), what are the Hazard Ratio (HR), the lowest-APF compliant respirator class, and its Maximum Use Concentration (MUC)?

  1. HR = 28.0; a loose-fitting PAPR (APF = 25, MUC = 1,250 ug/m^3) is the lowest-APF compliant respirator.
  2. HR = 28.0; a full-facepiece APR (APF = 50, MUC = 2,500 ug/m^3) is the lowest-APF compliant respirator.
  3. HR = 28.0; a full-facepiece PAPR (APF = 1,000, MUC = 50,000 ug/m^3) is mandatory whenever silica exceeds 1,000 ug/m^3.
  4. HR = 14.0; a half-mask APR (APF = 10, MUC = 1,500 ug/m^3) is sufficient once qualitative fit testing is documented.
Show the answer

B. HR = 28.0; a full-facepiece APR (APF = 50, MUC = 2,500 ug/m^3) is the lowest-APF compliant respirator.

The Hazard Ratio is HR = C / PEL = 1,400 / 50 = 28.0, meaning the selected respirator must have APF >= 28 and MUC = APF * PEL >= 1,400 ug/m^3 (while never exceeding IDLH). A half-mask APR (MUC = 10 * 50 = 500 ug/m^3) and loose-fitting PAPR (MUC = 25 * 50 = 1,250 ug/m^3) are both inadequate. A full-facepiece APR (APF = 50) provides MUC = 50 * 50 = 2,500 ug/m^3 (>= 1,400 and < 50,000 IDLH), making it the lowest-APF compliant choice.

Reference: OSHA 29 CFR 1910.134(d)(3)(i) Table 1 (Assigned Protection Factors & Maximum Use Concentration)